Local Law 126 Parking Structure Inspections: Who Files, How Often and When Each Borough Is Due
Published November 8, 2026
Who has to inspect a parking structure, how often and by when?
If you own a parking structure covered by Local Law 126 of 2021, you have to hire a New York State licensed professional engineer to inspect it at least once every six years and file a report with the Department of Buildings (DOB).
The filing window depends on where the garage is. Each window lasts two years. Manhattan Community Districts 1 to 7 filed in 2022 to 2023. Brooklyn and the rest of Manhattan filed in 2024 to 2025. The Bronx, Queens and Staten Island have until December 31, 2027.
DOB announced the law in a November 23, 2021 service notice. The operating rule is 1 RCNY 103-13.
If you want the basics plus the fee-schedule discrepancy and the initial-observation requirement, see our earlier Local Law 126 guide.
What are the filing windows by borough?
The staggered cycle started January 1, 2022 and repeats every sixth year.
| Where the garage is | Window |
|---|---|
| Manhattan Community Districts 1 to 7 | Jan 1, 2022 to Dec 31, 2023 |
| Rest of Manhattan, all Brooklyn districts | Jan 1, 2024 to Dec 31, 2025 |
| All Bronx, Queens and Staten Island districts | Jan 1, 2026 to Dec 31, 2027 |
DOB’s diagram labels these Sub-cycles 1A, 1B and 1C within Cycle 1, which runs 2022 to 2027. Under the rule, each window comes back every sixth year. That means the next window for Manhattan districts 1 to 7 opens January 1, 2028.
As of November 8, 2026, the Bronx, Queens and Staten Island deadline is 418 days away.
Don’t miss the 60-day clock after the QPSI finishes the assessment. The report has to reach DOB within 60 days. If it doesn’t, a new assessment is required.
Which garages are covered, and who inspects?
DOB defines a parking structure as a building or portion of a building used for parking or storing motor vehicles, including space inside or under a building. That includes open and enclosed parking garages.
The exclusions are the ones listed in the FAQ above. DOB also has a Parking Structure Inspections Map, but says it’s still the owner’s responsibility to decide whether the structure is subject to the rule. The rule also lets the owner or QPSI file a Verification Request to confirm coverage.
The inspection must be done by a QPSI. DOB’s FAQ says a QPSI is a professional engineer with three years of relevant experience, in good standing. The owner hires the QPSI. The QPSI sets the inspection program and files in DOB NOW: Safety.
What does the inspection involve?
Under 103-13(c), the QPSI has to review the most recent compliance report, the prior cycle’s annual observation checklists, any design or repair drawings, violations and FISP reports before starting.
Then comes the condition assessment. It covers structural components, waterproofing, fireproofing and fire stopping, and wearing surfaces.
DOB is specific about what has to be looked at and what has to be physically checked. The FAQ says 100% of structural elements get a visual inspection. Physical examinations, meaning sounding, probing or testing beyond a visual look, must be performed on a minimum of 10% of each structural element, including beams, columns and slabs.
The final inspection has to include a complete walkthrough of each level dedicated to parking. A drive-by does not count.
Facade scope depends on the building. If the building is subject to FISP, the facade does not have to be included in the parking report. The same is true when parking occupies less than 50% of the building’s square footage.
Per DOB’s FAQ, if a building is 4 to 6 stories and more than 50% of the total area is parking, the entire facade must be visually examined and 10% physically examined. Another FAQ answer says the QPSI covers the facade where 50% or more of the square footage is parking and the building is not under FISP.
If your building falls under both sets of rules, the FISP side follows its own rule. The parking rule also lets the owner of a FISP building ask to move the parking window to the next FISP window so both reports can be filed together. That request has to reach DOB 180 days before the end of the assigned parking window.
For new buildings, the first filing comes six years after the first Temporary, Interim or final Certificate of Occupancy, if that date falls in the window. If not, it goes into the next cycle’s window.
What do Safe, SREM and Unsafe mean for a garage?
- Safe: needs no repair or maintenance and will remain safe during the next six years.
- SREM (safe with repairs and/or engineering monitoring): safe now, but needing repair or maintenance within one to six years to prevent it from becoming unsafe. The report must give the date work must be performed (MM/DD/YYYY), and the rule does not accept less than one year, “ASAP” or “immediately”.
- Unsafe: hazardous to persons or property. Repairs must start immediately and conditions be corrected within 90 days of submission, with an amended report within two weeks of completion.
An SREM rating carries more engineering than a FISP SWARMP. The report must include a monitoring plan, or say plainly that only repairs are needed. It also has to name the engineer doing any monitoring and include a stability analysis of typical and worst-case framing members. DOB’s FAQ says stability analysis is always required for SREM reports.
The 18-to-24-month follow-up in the FAQ above applies to SREM reports. The same condition at the same location cannot be SREM in two consecutive cycles. If an SREM condition is not corrected, it must be reported Unsafe at the next inspection.
For Unsafe garages, DOB’s FAQ makes one repair point plain. Shoring should not be used in areas open to vehicular traffic, because vehicle impact can dislodge it. The QPSI is responsible for guidance on protecting the public.
What must the owner do between filings?
Once the report is accepted, you have to have an annual observation done each year using the QPSI-prepared checklist from that report.
Those completed checklists stay on site. DOB’s FAQ says they must be available on request and are not submitted to DOB until they are included with the next cycle’s report under the rule.
This is not a stock checklist. The QPSI prepares a unique checklist for each structure during each condition assessment so it reflects that garage’s own elements.
What are the penalties?
From 103-13(e): late filing is $1,000 per month, starting the day after the window closes and running until an acceptable report is filed.
Failure to file is $5,000 per year beginning one year after the window ends.
Failure to correct an Unsafe condition within 90 days is $1,000 per month until corrected or extended.
An SREM condition not corrected and refiled as Unsafe carries a one-time $2,000 penalty.
The rule allows an extension of up to 90 days on the QPSI’s application. That application requires a copy of the repair contract and progress photos. Financial considerations are not accepted as a reason.
Where does repair work come in?
The QPSI inspects and files. Altius CM is a repair contractor that works with the owner’s QPSI on the repairs that follow.
Two project files show the range of garage work. 14 53rd Street in Brooklyn, a completed $80K+ job, repaired cracked and spalled concrete encasement and slab-on-grade, rusted steel beams and headers, and part of the garage ramp with a new trench drain, and cleaned out and tested the existing drains and sump pits.
330 West 45th Street in Manhattan, a $150K+ job in progress, covers concrete repair at columns, slabs, beams and walls, plus crack repair and shoring of utilities.
See parking garage repair, and if a structural member is failing now, emergency structural repair.
Sources
- NYC DOB, Parking Structures
- 1 RCNY 103-13 (PDF)
- DOB service notice, Nov 23, 2021 (PDF)
- DOB, Staggered Filing Cycle diagram (PDF)
- DOB, PIPS FAQ
- DOB, Classifications & Reporting
Last verified: November 8, 2026. Confirm your structure’s coverage and window in DOB NOW: Safety and with your QPSI. This is general information, not legal advice.
Frequently asked questions
Who has to file a parking structure report under Local Law 126?
Owners of buildings that contain a parking structure, meaning a building or portion of a building used for parking or storing motor vehicles, including open and enclosed garages. DOB's exclusions include autobody and automotive repair shops, showrooms, service stations, garages for fewer than three cars, unenclosed and unattached lots, and private garages serving one- and two-family homes.
Who is allowed to inspect a parking structure?
A Qualified Parking Structure Inspector (QPSI). DOB's FAQ describes a QPSI as a professional engineer with three years of relevant experience, in good standing and designated by DOB. The owner hires the QPSI. A contractor does not inspect or file the report.
What is the deadline for a Bronx, Queens or Staten Island garage?
The window for Community Districts in those boroughs runs January 1, 2026 to December 31, 2027 under 1 RCNY 103-13 and DOB's published cycle diagram. As of November 8, 2026 that is 418 days away.
What is the annual observation, and do I file it?
After a report is accepted, the owner must have an annual observation done each year using the checklist from the accepted report, by or under the direct supervision of a QPSI. Per DOB's FAQ, completed checklists are kept on site and available on request, and are not submitted to DOB until they go in with the next cycle's report under the rule.
What extra step applies to an SREM rating?
A condition assessment is required no earlier than 18 months and no later than two years after the initial filing, with an amended report filed within 60 days of the final inspection and no later than two years after the initial filing. The exception is a report filed less than one year before the next cycle's window starts.